Just another WordPress weblog

Bell and Gosset NRF-36 3-Speed Pump 103400 Circulator Pump 1 flange set include


Bell and Gosset NRF-36 3-Speed Pump 103400 Circulator Pump 1 flange set include


Bell and Gosset NRF-36 3-Speed Pump 103400 Circulator Pump 1 flange set include


Bell and Gosset NRF 36 Three Speed Pump. With 1 flat flange set. Our exceptional Bell and Gosset NRF 36 pump is designed for distances of over 100 feet. Keep in mind that if the pump is located in the back of the stove that you must double your distance (round trip there and back). PUMP CURVES AND LITERATURE. Residential and Light Commercial Heating Systems. 20 at 18.5. Face to Face Dimension In. 3.75 at 1. Wet Rotor, Maintenance Free. Hot Water Circulating Pumps. Single-phase models are thermally protected. Cast-iron units are not for potable water. DuraGlide bearing system ensures high starting torque for dependable seasonal start-ups. Self-cleaning particle shield protects the shaft and bearings from start-up debris. Closed impeller design ensures efficient operation. Ceramic shaft, carbon bearings, and high-nickel stainless steel rotor. Working pressure: 150 psi. 240°F (cast-iron); 230° (bronze). Circulator Pump, Closed Loop System, 1/6 HP, 1 Phase, Voltage 115, 2.3 Amps, Inlet/Outlet Flanged, Housing Material Cast Iron, Max. Working Pressure 150 PSI, Shut-Off 32.5 Ft. We offer service even after the sale! 7 days a week! Over 10 years experience! Tired of talking to dealers and sellers who don’t even know their own products? Unlike others, we service what we sell! Our feedback is earned! We just want to take the time to thank your for the opportunity to service you and your project! We enjoy answering questions and helping your project run a little smoother! The item “Bell and Gosset NRF-36 3-Speed Pump 103400 Circulator Pump 1 flange set include” is in sale since Tuesday, April 30, 2013. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\HVAC Parts & Accessories”. The seller is “freeheat4u” and is located in Plymouth, Wisconsin. This item can be shipped to United States, Canada.

  • MPN: Does Not Apply
  • Brand: Bell and Gossett nrf36
  • Model: Bell 3-Speed NRF-36 / flat flanges
  • Horse Power:: 1/6
  • Max Temp:: 240 Degrees
20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20×20 Water to Air Heat Exchanger1 Copper Ports w/ EZ Install Front Flange. 20×20 / 160,000 BTUs / 180 PSI. For use in your hot air furnace plenum. Not recommended for air compressors. Information about our heat exchangers. This heat exchanger is ideal for a 20″x 21″ plenum or larger. The outlets come out on the 20 side (shown as the vertical side in the picture above). The fin area is 20″x 20″. There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Outside Dimensions 20(width)x23.5(Length from Manifold to Base)x3.5(Thickness). Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. Installation brackets for installing water to air heat exchangers inside of furnace plenums. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. As a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Water to Air heat exchangers, often called duct coils or furnace radiators, are uséd for installing into forced air furnace to provide heat from hot water. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. 24×24 w/1 1/4 ports. 30×30 w/1 1/4 ports. 36×36 w/1 1/4 ports. The item “20×20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange” is in sale since Thursday, June 20, 2019. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.

  • Brand: Undisclosed
  • MPN: Does not apply
  • UPC: 689807252500
OUTDOOR WOOD FURNACE BOILER PUMP FLANGE SET 1' BRONZE LEAD FREE NFS 372 WithBLEED


HERE IT IS 1 INCH LEAD FREE FULL PORT BALL VALVE FLANGE KIT WITH NEW FILL AND BLEED KIT. THE NUMBER 1 PROBLEM WITH PUMPS GOING BAD IS AIR CAUGHT IN THE HEAT EXCHANGERS!!! NO AMOUNT OF BLEEDERS CAN SOLVE THIS PROBLEM SO WITH OUR YOU CAN HOOK UP A HOSE TO THE FLANGE AND PUSH ALL AIR BACK TO THE STOVE. IT ALLOWS YOU TO BLEED WITH WATER PRESSURE BOTH WAYS FROM ONE POINT BY CLOSING BALL VALVES ON FLANGES. YOU CAN ALSO FILL THE STOVE WITH THIS ATTACHMENT AS WELL. THERE IS NO BETTER SET UP TO SOLVE YOUR PUMP PROBLEMS THAN THIS FLANGE SET. THESE ARE SAFE FOR POTABLE WATER AS WELL. INCLUDES 2 GASKETS AT NO CHARGE. We offer service even after the sale! 7 days a week! Over 10 years experience! This is all we do, so give us a call and let our knowledgeable staff help you. Tired of talking to dealers and sellers who don’t even know their own products? Unlike others, we service what we sell! Our feedback is earned! All others must call for a quote. We just want to take the time to thank your for the opportunity to service you and your project! We enjoy answering questions and helping your project run a little smoother! The item “OUTDOOR WOOD FURNACE BOILER PUMP FLANGE SET 1′ BRONZE LEAD FREE NFS 372 WithBLEED” is in sale since Thursday, May 22, 2014. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “freeheat4u” and is located in Plymouth, Wisconsin. This item can be shipped to North, South, or Latin America, all countries in Europe, Australia.

  • MPN: Does Not Apply
  • Brand: AMERICAN ROYAL
  • Model: AM BLEEDER FLANGE SET
  • Size: 1″ FNPT
20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20x20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange


20×20 / 160,000 BTUs / 180 PSI. For use in your hot air furnace plenum. Not recommended for air compressors. Information about our heat exchangers. This heat exchanger is ideal for a 20″x 21″ plenum or larger. The outlets come out on the 20 side (shown as the vertical side in the picture above). The fin area is 20″x 20″. There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Outside Dimensions 20(width)x23.5(Length from Manifold to Base)x3.5(Thickness). Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. Installation brackets for installing water to air heat exchangers inside of furnace plenums. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. These heat exchangers are to be hooked up to a boiler or a chilled water source. When hooked up to your boiler or chilled water source, these heat exchangers can also be used as a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Water to Air heat exchangers, often called duct coils or furnace radiators, are used for installing into forced air furnace to provide heat from hot water. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. 24×24 w/1 1/4 ports. 30×30 w/1 1/4 ports. 36×36 w/1 1/4 ports. The item “20×20 Water to Air Heat Exchanger1 Copper Ports with EZ Install Front Flange” is in sale since Tuesday, June 12, 2018. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.

  • Brand: Badgerpipe
  • Model: 20×20
  • Type: Heat Exchanger
  • MPN: 20×20
16x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


16x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


16x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


16x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


16x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


16×18 / 115,200 BTUs / 100 PSI For use in your hot air furnace plenum. Please see charts in above pics. Not recommended for air compressors. This listing does not include the install kit. Information about our heat exchangers. This heat exchanger is ideal for a 16″x 19″ plenum or larger. The outlets come out on the 16 side (shown as the vertical side in the picture above). The fin area is 16″x 18″. Outside Dimensions 16(width)x21.5(Length from Manifold to Base)x3.5(Thickness). There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. Installation brackets for installing water to air heat exchangers inside of furnace plenums. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. These heat exchangers can also be used as a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Check our other listings for an installation kit that makes it super easy to do the entire installation. Water to Air heat exchangers, often called duct coils or furnace radiators, are used for installing into forced air furnace to provide heat from hot water. They can be installed into the cold air side of the furnace if that is the best option. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. The item “16×18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange” is in sale since Wednesday, February 4, 2015. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.

  • Type: Heat Exchanger
  • MPN: 16×18
  • Brand: Badgerpipe
  • Model: 16×18
18x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


18x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


18x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


18x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


18x18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange


18×18 / 129,600 BTUs / 100 PSI For use in your hot air furnace plenum. Please see charts in the pics above. Not recommended for air compressors. This listing does not include the install kit. Information about our heat exchangers. This heat exchanger is ideal for a 18″x 19″ plenum or larger. The outlets come out on the 18 side (shown as the vertical side in the picture above). The fin area is 18″x 18″. Outside Dimensions 18(width)x21.5(Length from Manifold to Base)x3.5(Thickness). There is a 1 frame on the end opposite the outlets that covers the copper elbows. This makes the area inside of your plenum 1 longer. All exchangers are 3 1/2 thick. Aluminum fins are installed at 12 fines per inch. All exchangers are triple pass design. Tubing is 1/4 copper. All our exchangers include the flat front face mounting for easier installation and increased plenum strength. Our exchangers have 1 copper outlets and can be installed with either sweat fittings or push fit type fittings like sharkbite’s. Exchangers will work with chilled water also. We stock many sizes, always order the largest size that will fit into your plenum. Installation brackets for installing water to air heat exchangers inside of furnace plenums. This easy to install kit takes all of the work out of installing a coil. Great for the do it yourselfer or the seasoned installer. Even most that are listed as 4″ are actually 3.5″. These heat exchangers can also be used as a stand alone heat source by simply attaching a fan or squirrel cage to one side of the unit. They can be installed in either the hot air side or the cold air return of a furnace. Please note that if installed in the cold air return you will need to install a 3 way zone valve in order for the fan to operate properly. This heat exchanger is of a new style which does not require bending of your duct work. This new style heat exchanger can be easily installed by just slipping it into the plenum and attaching with self threading screws. You will not need any special tools to install. This unit is easier to install than others on the market because it attaches from the front instead of the side. Check our other listings for an installation kit that makes it super easy to do the entire installation. Water to Air heat exchangers, often called duct coils or furnace radiators, are used for installing into forced air furnace to provide heat from hot water. They can be installed into the cold air side of the furnace if that is the best option. They work in much the same way as the central air conditioning unit. The following things should be taken into consideration when installing a duct coil. (1) Size the coil so that the fins take up the maximum amount of the plenum as possible. (2) Securely fasten the unit so that it doesn’t rattle. (3) Make sure there are no foreign objects are touching the fins or the tubes. (4) Duct tape any air leaks. (5) Do not bend the fins. If you do, straighten them as best you can. A tool called a “Rake” is available for straightening the fins. (6) If you are going to run your outside heat in the summer install a bypass valve. (7) A duct coil installation kit makes installing the heat exchanger easier. The item “18×18 Water to Air Heat Exchanger 1 Copper Ports with EZ Install Front Flange” is in sale since Thursday, February 5, 2015. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners & Heaters\Furnaces & Central Heating Systems”. The seller is “badger-pipe” and is located in Mauston, Wisconsin. This item can be shipped worldwide.

  • Type: Heat Exchanger
  • MPN: 18×18
  • Brand: Badgerpipe
  • Model: 18×18