Just another WordPress weblog

410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose


410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose


410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose


410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose


410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose


Gregoriou Brothers Refrigeration Since 1979. 410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose. This kit is for Recharging Refrigerant R-410a Systems. Refrigerant R410a&###xA0;is used on almost all “NEW” A/C Units and almost all of the “mini-split” &###xA0;A/C systems. As R-22 is being phased out, R-410a is now the refrigerant found on all “NEW” A/C Systems. This recharge kit includes. Can of R-410a with a 1/4 male flare fitting on top with internal valve core and brass cap as pictured. (1)&###xA0;Reusable&###xA0;, Quick Connect (screw-on), Top Mount Can Taper with color coded charging gauge for R410a systems. (1)&###xA0;&###xA0;SPECIAL, R410a, COLOR CODED, “CHECK & CHARGE-IT” &###xA0;Gauge. (1) CPS AD87 R410a adapter Fitting. Normal R410a low-side system pressure while unit is running is; 120 to 150 psi. Depending on the outdoor and indoor temperature. Some R410a systems still use the 1/4 male flare so in this case the charging hose with this kit will connect directly onto it. The charging hose on this kit has the larger 5/16 connection with valve core depressor. You will need this special hose because the new size found on almost all mini-splits and some R410a A/C systems is now larger (5/16) to prevent mixing, &###xA0;&###xA0;so now you will have everything you need to recharge a R410a system. You will have to pay your custom charges and all other charges that apply in Canada. We have no way of knowing what those charges are or will be. You can contact your local UPS store with questions on your costs for custom charges. The&###xA0;declared&###xA0;value is: 156.00. THIS IS DIRECTLY FROM THE US-EPA WEB SITE. Does the EPA REFRIGERANT sales restriction apply to HFC refrigerants? The refrigerant&###xA0;sales restriction only applies to refrigerants consisting of an ozone-depleting substance. Therefore, &###xA0; HFC refrigerants&###xA0; such as&###xA0;R-134a, &###xA0;and&###xA0; HFC refrigerant blends&###xA0; that do not contain an ozone-depleting substance, &###xA0;such as&###xA0;R-404A&###xA0;and&###xA0;R-410A, &###xA0;are not currently covered under the EPA Refrigerant&###xA0;sales restriction. FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS. USE ONLY IN AIR CONDITIONING SYSTEMS DESIGNED FOR R410A. DO NOT MIX WITH ANY OTHER REFRIGERANT. &###xA0; Refrigerant Can Notes. ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS. ALWAYS WEAR GLOVES WHEN WORKING WITH REFRIGERANTS. VAPOR HARMFUL SKIN AND EYE IRRITANT. DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO. &###xA0;BURST AND RESULT IN SERIOUS INJURY. ALWAYS REPAIR LEAKS BEFORE ADDING REFRIGERANT. USE ONLY IN SYSTEMS DESIGNED FOR&###xA0;REFRIGERANT R410A. FOR&###xA0;LOW PRESSURE SIDE&###xA0;OF THE SYSTEM ONLY!!! DO NOT EXPOSE THIS CAN TO HEAT OR STORE IN TEMPERATURES ABOVE 120 F. HIGH TEMPERATURES MAY CAUSE THE CAN TO BURST. DO NOT PUNCTURE OR INCINERATE THIS CAN. DO NOT STORE IN PARKED VEHICLES WHERE THE INSIDE TEMPERATURE MAY EXCEED 120 F. Do not refill can. KEEP OUT OF REACH OF CHILDREN. Refrigerant R410a is used on almost all “NEW” A/C Units and almost all of the “mini-split” A/C systems. This recharge kit includes; (1) 28 oz. (1) Reusable , Quick Connect (screw-on), Top Mount Can Taper with color coded charging gauge for R410a systems. (1) SPECIAL, R410a, COLOR CODED, “CHECK & CHARGE-IT” Gauge. (1) CPS AD87 R410a adapter Fitting Normal R410a low-side system pressure while unit is running is; 120 to 150 psi. You will need this special hose because the new size found on almost all mini-splits and some R410a A/C systems is now larger (5/16) to prevent mixing, so now you will have everything you need to recharge a R410a system. The declared value is: 156.00 THIS IS DIRECTLY FROM THE US-EPA WEB SITE; Does the EPA REFRIGERANT sales restriction apply to HFC refrigerants? The refrigerant sales restriction only applies to refrigerants consisting of an ozone-depleting substance. Therefore, HFC refrigerants such as R-134a, and HFC refrigerant blends that do not contain an ozone-depleting substance, such as R-404A and R-410A, are not currently covered under the EPA Refrigerant sales restriction. Epa FOR USE BY QUALIFIED Refrigeration and Air Conditioning TECHNICIANS. Refrigerant Can Notes WARNING ALWAYS WEAR EYE PROTECTION WHEN WORKING WITH REFRIGERANTS. DO NOT CONNECT THIS CAN TO THE HIGH PRESSURE SIDE OF THE SYSTEM, THIS MAY CAUSE THE CAN OR CONTAINER TO BURST AND RESULT IN SERIOUS INJURY. USE ONLY IN SYSTEMS DESIGNED FOR REFRIGERANT R410A. FOR LOW PRESSURE SIDE OF THE SYSTEM ONLY!!!! The item “410A, R410a, R-410a, Refrigerant Refill Kit Gauge & Special 5/16 Charging Hose” is in sale since Monday, August 07, 2017. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners”. The seller is “john102561″ and is located in Hartford, Wisconsin. This item can be shipped worldwide.

  • Brand: frosty freeze refrigerant
  • MPN: R410a
  • Model: 410a
  • Energy Star: R-410a