Just another WordPress weblog

Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE


Mini Ductless Split Air Conditioner 24000 BTU Cassette. 24000 BTU ENERGY STAR Ceiling Cassette Split AC. 21 SEER Efficiency w/ Heat Pump Technology. The 24000 BTU this Dual Zone INVERTER mini split AC. With Ceiling Cassette can cool or heat TWO separate zones (2 x 12000 BTU) for a total coverage area of 1200 ft². The Air handlers are discreetly recessed into a ceiling panel – only the grill is visible. 21 SEER Inverter technology with ENERGY STAR Certification provides the benefits of low operation temperatures, rapid cooling / heating, as well as maximum energy efficiency. R410A Pre-charged – 2 X 15′ Installation linesets Included. 24,000 BTU INVERTER Heat Pump Capacity. 21 SEER – 10.2 HSPF – AHRI / ENERGY STAR Certified. Dual-Zone Ceiling Cassette Setup. Pre-Charged with ECO-Friendly R410A. Indoor Unit – CEILING CASSETTE Air Handlers. Digital Multi-function LCD Remote Controls. 15ft Copper Refrigeration Linesets. Filtration Screens – Multi Folds Evaporator. Product and Installation Manual. Rated Capacity of Condenser will be less than actual capacity in above configuration. Rated Capacity is not the same as Maximum Capacity. For Capacity Calculation Table. System available with true 2-Ton Condenser. Click here for listing. 21 SEER – 10.2 HSPF – ENERGY STAR. Most Energy Efficient Dual-Zone Series on Market. Dual Air Handlers Mounts Discreetly in Ceiling. Dry-Mode removes moisture w/o affecting room temp. Cross Flow Technology reduces noise output. Compatible with over 5 Filtration medias. COMPRESSOR BELT Hyper heats for Maximum Heat. Low Ambient Temperature Operation (5° F). Restart IC: Settings restored Following Power Outage. Follow-Me Function tracks Remote Location. The particle filter or pre-filter removes dust and other air-borne pathogens before pushing the air through additional filtration medias and the refrigeration coil array. This filter is washable and comes factory installed with every ductless air conditioner system. The open channel construction of the 3M High Air Flow (HAF) filter offers low initial airflow resistance, while its unique microstructure and electrostatic charge provides effective particle capture and retention. This translates into fewer filter change outs and reduced coil cleaning. The Vitamin C Filtration media releases Vitamin C into the air which softens skin and reduces stress among other therapeutic benefits. A good choice for those wanting to add some invigoration to their indoor air environment. Filter lasts over 2 years. The anti-microbial effect of silver ionic technology kills allergy causing bacteria by destroying the inner configuration elements of the cell body. The nano-silver attached to the filter screen constantly releases silver ions which directly eliminates and prohibits bacteria from replicating. Eliminates odors such as ammonia and deactivates harmful chemicals has such as formaldehyde. By forming positive positions on the filter surface, Electrostatic Fiber traps small dust particles, smoke and pet dander to prevent allergic reactions and neutralize odor in the air. 12000 BTU Indoor Unit specs CLICK FOR FULL SPEC SHEET. 230 V / 60 Hz / 1Ph. Body Dimensions (W x D x H). 22.44″ × 22.44″ × 10.24 inches. Panel Dimensions (W x D x H). 25.47″ x 25.47″ x 2 inches. VIEW FULL AIR HANDLER SPECIFICATION SHEET >>>. Outdoor Unit (condenser) specs CLICK FOR FULL SPEC SHEET. 24000 BTU (12k x 2). 5 – 122 F (cool and heat). R410A / 68oz Charge. Max Lineset Length (1 zone). Max Lineset Length (all zones). 1/4″ x 3/8″ (2). Dimensions (W x D x H). 33 1/4 × 12 1/2 × 27 1/2 inches. VIEW FULL CONDENSER SPECIFICATION SHEET >>>. CLICK TO VIEW COMBINATION CALCULATION TABLE >>>. 15 Feet Flared Copper Tubing. 15 Feet Pipe Insulation. Condenser Rubber Feet pads. Wall Bracket for Indoor Unit x 2. For Alternate lineset sizes. Extend included 15 foot copper lineset to 25-30-40-50-65 feet. DOES NOT INCLUDE ELECTRICAL WIRE BETWEEN INDOOR > OUTDOOR. WHAT IS DC INVERTER? DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called “DC inverter” because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. YMGI Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly. Once the set temperature is reached, it slows down and adjust its capacity to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature. BASIC OVERVIEW: The installation of a ceiling cassette is much like that of a ductless mini split with the exception that instead of a wall mounted air handler, a ceiling cassette mounts in the ceiling usually as a flush mount or in a drop ceiling. The indoor unit (ceiling cassette) and outdoor unit (condenser) are connected to each other by means of refrigerant copper tubing and electrical cables that are routed through the ceiling and outside to the condenser outputs via a 2-3 inch hole. The compressor comes pre-charged with freon however, procedures such as conducting leak tests etc. Are still important steps in ensuring proper functioning of a ceiling cassette system. Click for Installation Tip. Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a ceiling cassette system. Click to Download Installation manual. 5 Year Compressor – 1 Year on all other Parts Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not “plug-n-play” units that can be properly installed without certain tools any prior HVAC – electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Failure to provide valid contact# will delay order. Provides Flat even surface – Avoids debris obstruction. Lineset (1/4 x 1/2). Required for Installation 25ft – 30ft – 40ft – 50ft. Mount your condenser at any height on an outdoor sidewall. Required when mounting air handler on Interior wall. 16/4 Electrical Wire Harness – For Extending Evap. Spare remote controls for the T1 Series Ductless System. Inserts into Filter Screen Slot – Choice of 4 Filtration Medias. Permanently Hard Mounts – Controls Settings w/ Remote. Swap 1-12k Mount for Suspended Ceiling. Swap 2-12k Mount for Suspended Ceiling. Swap 1- 12k Mount for Wall Mounted. Swap 2- 12k Mount for Wall Mounted. And request invoice with preferred options. View the Mini Split FAQ >. View the Mini Split Outline Diagram >. The free listing tool. The item “Dual Zone Ductless Mini Split Air Conditioner 2 x 12000 BTU CEILING CASSETTE” is in sale since Wednesday, September 09, 2015. This item is in the category “Home & Garden\Home Improvement\Heating, Cooling & Air\Air Conditioners”. The seller is “gameroomfanatic” and is located in Oak Park, Michigan. This item can be shipped to United States, to Canada.

  • Brand: Thermocore
  • MPN: 24,000 BTU 12,000 x 2 INVERTER ENERGY STAR 21 SEER
  • Type: Split System
  • Cooling BTU/Hr: 24000
  • SEER: 19
  • Energy Star: With ENERGY STAR®
Share and Enjoy:
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google
  • E-mail this story to a friend!
  • Furl
  • LinkedIn
  • Live
  • MySpace
  • Print this article!
  • Propeller
  • Reddit
  • description
  • Slashdot
  • Spurl
  • StumbleUpon
  • Technorati
  • TwitThis
  • YahooMyWeb
NO COMMENTS

Sorry, the comment form is closed at this time.